NO, only on the wall that is at the top or bottom does not matter.
Yes!!! keeping in mind two considerations that the monobloc as well as any heat pump air conditioner is not to be considered as an electric stove, i.e. it has pressure drops as it approaches 0 ° and is extremely influenced by external humidity, secondly it is necessary to correctly size the thermal load necessary for an environment based on precise thermotechnical calculations of losses and transmittances of the buildings. Be wary of empirical calculations: some monoblocks have additional heating systems such as (PANAMA, KYOTO, METROPOLIS 12HP + R) the water and ues units have yields certified by the manufacturer and higher parameters.
If the length of the coaxial tube is greater than that foreseen by the house, I have a deterioration in the performance of the monobloc proportional to the length of the tube and in any case it is recommended by the manufacturer not to exceed the maximum linear meters imposed. Each sharp bend equals one meter.
It is preferably 45 ° or 90 if not immediately after the first 25cm of air outlet. Each curve affects approximately 10% of the machine’s power.
Yes, in some cases up to three meters, but it is always better to be assisted by an authorized center and a professional who evaluates the impact.
Nothing the machine restarts in the previously set function and mode.
Not if the gutter is your property and you are in a single house.
Yes always if you are in an apartment because of the sentence of the Trib of Padua nr. 352 or have the written permission signed by the assembly of condominiums for change of intended use of the common part.
Yes, on some models it is possible to install a very practical KIT from the house that eliminates condensation and allows the conditioning unit to have no condensation evacuation in both cooling and heating modes.
First Evaluate the correct installation Second check that the power of the machine is adequate for the environment to be cooled / heated, according to the characteristics of the manufacturer.
It is sufficient that the wall is perimeter, that is, that the monobloc has the possibility of having a hole directed towards the outside.
It means in English Heat Pump that is an appliance equipped with a heat pump for heating.
No outdoor Unit AC and Split have different efficiency classes according to the parameters of the current legislation
Are efficiency classes that give quality and energy saving to the product and refer to the EER / SEER or COP / SCOP that is the ratio between the power output and the electricity consumed to obtain it, the higher the ratio, the better the efficiency of the machine, the class of merit is defined by law.
Simply by looking at the power of the machine in KW on the label and not their abbreviations.
Yes, of course, because you have to consider that inside the machine, although soundproofed, there is a compressor that is normally outside, and two fans for internal air ventilation and one for expelling the air.
Yes, it is better to build a support frame and call a professional installer.
Because it uses a coaxial system such as that of boilers for the suction and expulsion of the condenser air, which allows according to our technology to have equal or better than the competition.
Excellent question .. Our filters, although not original, improve the air quality compared to the original ones because we combine twenty years of experience in filtration with an AEMINA patent. Our AKTIVO filters are lab certified. Accredited minister of welthy in Italy.
Go to the section here and watch the video.
The white filter is a passive electrstatic filter that attracts and traps all the moldy spore bacteria that pass nearby and eliminates them thanks to AEMINA which is a very powerful antibacterial. The Gray filter is a titanium dioxide filter that has the additional antimicrobial function.
It is a powerful antibacterial agent that associated with the filters allows a complete cleaning of the air from polluting agents, bacteria in general, even dangerous for human health The system does not release into the environment intermediate or secondary products dangerous for human health, as in the case of sterilization UV (which during the bactericidal action produces ozone molecules) or the use of sterilizing gases such as ozone, ethylene oxide, etc. or like other sanitizers that kill by poisoning. It works in short like an air balloon (bacterium) attached to a pin (aemina).
No Absolutely, the white ones would lose the electrostatic charge making them ineffective, the GRAY ones would melt, being in ecological paper.